Controller Configuration

Configure the Controller inputs and outputs for this appliance.

Enter Oven Set Up screen
as described previously.

Touch

X

in any screen

displayed to return to the
previous screen.

Touch Factory Cfg.

Touch T beside
parameter.

P1 & P2 toggle between
OFF, Cook & Product
temperature.

S1 & S2 toggle between
OFF, End & Extra Time.

Touch to SAVE settings.

Hyst: change control
hysteresis from 1F to 10F in
1F increments.

Ex T: toggles extra time
increments between 1 min.
and 5 min.

T Off: adjusts cook
temperature offset between

-50F & +50F in 1F
increments.

D Alm: toggles 25F door
alarm ON or OFF.

Pre T: adjust idle shutdown
time from OFF to 10, 20 or
30 min.

SmCk: adjust intuitive cook
factor from OFF to values 5-
15 in 0.5 increments.

Touch T beside
parameter.

R1, R2 & D1 toggle
between OFF, Heat, Fan
Power, Lamp & Fan
Speed.

V1 toggles between OFF
& Fan Speed.

Touch to SAVE settings.

Touch E beside parameter
to open a numeric window to
enter parameter value.

Idle: idle power consumption.

Heat: heater power
consumption.

Fan: fan power consumption.

Touch to SAVE settings.

CK: measured Cook probe
temperature.
PR: measured Product
probe temperature.
End: state of End switch.
Ext: state of Extra switch.
(OP=open, CL=closed)
Heat: toggles Heat output
ON & OFF.
Lmp: toggles Lamp output
ON & OFF.
FanP: toggles Fan output
ON & OFF.
V1.10: software version
(value may differ).
FanS: toggles Fan Speed
between HI & LO.
Time: elapsed running time
of controller.