Temperature probe, Pushbutton switch contact blocks – BKI COq Convection Oven User Manual

Page 29

Advertising
background image

Convection Oven

Component Replacement

27

Temperature Probe

1. Disconnect the oven power supply by turning

OFF the circuit breaker in the power supply
service panel.

2. Remove the side panel from the control side of

the oven.

3. Loosen probe clamp retaining screw and slide

probe out of clamp.

4. Remove probe wires from the connector by

inserting a 1/8” [3 mm] flat screwdriver into the
release slots as shown. Insert wires from the
replacement probe into the connector in the
same manner. Probe is not polarized so it does
not matter which color wire is inserted into the
connector sections.

5. Insert the replacement probe into the clamp.

The replacement probe must protrude into the
cavity 5/8” [16 mm] as shown. Tighten the
retaining screw. Neatly coil the excess lead
length from the probe and tie wrap it so it does
not contact other oven components.

6. Reattach the side panel to the oven and turn

the power supply to the oven ON.

Pushbutton Switch Contact Blocks

1. Disconnect the oven power supply by turning OFF the

circuit breaker in the power supply service panel.

2. Remove the side panel from the control side of the oven.

3. Release the contact block mount from the pushbutton

operator by depressing the release cam.

4. Move the contact block(s) and mount to an accessible

position. Loosen the terminal retaining screws and
remove the wires from the contact block.

5. Remove contact block from mount by inserting a flat

screwdriver into the retaining clip on one side of the
contact block and prying up.

6. Snap replacement contact block into place on the mount.

Connect wires to replacement contact block.

7. Slide contact block mount back into position on the

pushbutton operator. Push the contact block mount in
until it snaps into place.

8. Reattach the side panel to the oven and turn the power

supply to the oven ON.

Advertising