Troubleshooting – BKI FW-15DTO Fry Warmer User Manual
Page 14
Fry Warmer
Maintenance
12
Troubleshooting
Refer to the table below for troubleshooting information.
Problem Cause
Possible
Solution
Warmer chute is not
holding heat
Ceramic heating
element failure
Contact an authorized BKI service agent for
corrective action.
Noisy fan
Fan blade is dirty or fan
bearings are failing
Contact an authorized BKI service agent for
corrective action.
FW-15/FW-15T/FW-15DTO (Bottom Breather)
Warmer chute is not
heating and perforated pan
is not heating
No power to unit.
Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.
Warmer chute is heating
and the perforated pan is
not heating
Fan has overheated and
cut off
Or
Heating coil has failed
Wipe the dust from the air intake louvers to allow
proper airflow and prevent fan overheating. Turn
the power switch off. Wait 60 seconds. Turn the
power switch back on.
Contact an authorized BKI service agent for
corrective action.
FW-12/FW-12T/FW-15 (Side Breather)
Warmer chute is not
heating and perforated pan
is not heating
No power to unit or main
switch is off.
Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.
Warmer chute is heating
and the perforated pan is
not heating
Fan has overheated and
cut off or fan has failed
Or
Heating coil has failed
Check to see if dust or any other object is blocking
the air intake. Remove blockage if necessary. If
problem persists contact an authorized BKI service
agent for corrective action.
Contact an authorized BKI service agent for
corrective action.