Fry Warmer

Maintenance

12

Troubleshooting

Refer to the table below for troubleshooting information.

Problem Cause

Possible

Solution

Warmer chute is not
holding heat

Ceramic heating
element failure

Contact an authorized BKI service agent for
corrective action.

Noisy fan

Fan blade is dirty or fan
bearings are failing

Contact an authorized BKI service agent for
corrective action.

FW-15/FW-15T/FW-15DTO (Bottom Breather)

Warmer chute is not
heating and perforated pan
is not heating

No power to unit.

Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.

Warmer chute is heating
and the perforated pan is
not heating

Fan has overheated and
cut off

Or

Heating coil has failed

Wipe the dust from the air intake louvers to allow
proper airflow and prevent fan overheating. Turn
the power switch off. Wait 60 seconds. Turn the
power switch back on.

Contact an authorized BKI service agent for
corrective action.

FW-12/FW-12T/FW-15 (Side Breather)

Warmer chute is not
heating and perforated pan
is not heating

No power to unit or main
switch is off.

Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.

Warmer chute is heating
and the perforated pan is
not heating

Fan has overheated and
cut off or fan has failed

Or

Heating coil has failed

Check to see if dust or any other object is blocking
the air intake. Remove blockage if necessary. If
problem persists contact an authorized BKI service
agent for corrective action.

Contact an authorized BKI service agent for
corrective action.