Installation

6

8. Connect wires of power cord to power entry terminal block according to the wiring diagram attached to

the unit or provided in the Service Manual.

9. Position main unit on the adapter and secure using #8 sheet metal screws.

10. Fit pan insert to main unit by lifting the open side of pan insert over the two tabs on main unit and lower

the pan insert into the opening in the adapter.

Countertop Cutout (FW-12 & FW-12T)

1. Obtain a suitable countertop location for the unit that will provide a clearance of 4” from the side louvers.

2. Cut a 12” x 20” hole in the countertop to fit the pan insert.

3. Using a 1/8” drill bit, drill holes in the countertop used to secure the main unit to the countertop.

4. Using a 2” hole saw, drill a hole in the countertop (under where the main unit will be secured) for the

power cord to pass through.

5. Feed power cord (supplied), up through hole in countertop.

6. Connect wires of power cord to power entry terminal block according to the wiring diagram attached to

the unit or provided in the Service Manual.

7. Position main unit on the countertop and secure using #8 sheet metal screws.

8. Seal main unit to the countertop after it is installed to conform to NSF Standard 4, Item 4.28. (Dow

Corning RTV #732 Multi purpose Sealant.)

9. Fit pan insert to main unit by lifting the open side of pan insert over the two tabs on main unit and lower

the pan insert into the opening in the countertop.

FW-15 (Side Breather)

Countertop Adapter (WN31206500)

1. Obtain a suitable countertop location for the unit that will provide a clearance of 4” from the side louvers.

2. Position the adapter (WN31206500) on the countertop.

3. Using a 1/8” drill bit, drill holes in the countertop used to secure the adapter to the countertop.

4. Using a 2” hole saw, drill a hole in the countertop (directly under the hole in the adapter) used for the

power cord to pass through.

5. Secure adapter to countertop with # 8 sheet metal screws.

6. Seal adapter to the countertop to conform to NSF Standard 4, Item 4.28. (Dow Corning RTV #732 Multi

purpose Sealant.)

7. Feed power cord (supplied), up through holes in countertop and adapter.

8. Connect wires of power cord to power entry terminal block according to the wiring diagram attached to

the unit or provided in the Service Manual.

9. Position main unit on the adapter and secure using #8 sheet metal screws.

10. Fit pan insert to main unit by lifting the open side of pan insert over the two tabs on main unit and lower

the pan insert into the opening in the adapter.

Advertising
This manual is related to the following products: