Fw-15 (bottom breather) – BKI FW-15DTO Fry Warmer User Manual

Page 9

Advertising
background image

Fry Warmer

Installation

7

Countertop Cutout

1. Obtain a suitable countertop location for the unit that will provide a clearance of 4” from the side louvers.

2. Cut a 16” x 18” hole in the countertop to fit the pan insert.

3. Using a 1/8” drill bit, drill holes in the countertop used to secure the main unit to the countertop.

4. Using a 2” hole saw, drill a hole in the countertop (under where the main unit will be secured) for the

power cord to pass through.

5. Feed power cord (supplied), up through hole in countertop.

6. Connect wires of power cord to power entry terminal block according to the wiring diagram attached to

the unit or provided in the Service Manual.

7. Position main unit on the countertop and secure using #8 sheet metal screws.

8. Seal main unit to the countertop to conform to NSF Standard 4, Item 4.28. (Dow Corning RTV #732 Multi

purpose Sealant.)

9. Fit pan insert to main unit by lifting the open side of pan insert over the two tabs on main unit and lower

the pan insert into the opening in the countertop.

FW-15 (Bottom Breather)

Countertop Collar Weldment With Liner Pan (WB31216000)

1. Obtain a suitable countertop location for the unit.

2. Cut holes in the countertop for the countertop collar weldment with liner pan (WB31216000) according to

illustration below:

3. Using a 1/8” drill bit, drill holes in the countertop used to secure WB31216000 to the countertop.

Advertising