Model G3B Gas burner — Instruction manual

Carlin part number MNG3B Gas Rev. 03/17/09

11

3. Wire burner

(continued)

Figure 7 Wiring diagram — wire routing

M

L1

L2

T

T

Red

Gray

Bk

Wh

Blue

Br

Or

Yel

24V

HSI

L1

L2

HSI

VALVE

VALVE (GND)

Red

Pur

Yel

Blue

Bk

Wh

Pur

MV

MV

TH/TR

Red

Bk

Bk

Bk

Wh

Bk

Gn

Yel

Bk

Red

Red

Bk

Bk

Motor
120

VAC

Motor

relay

Honeywell S89C
control

Hot surface
ignitor

40

Transformer

VA

Valve on
light

Terminal

strip

Motor

end switch

Thermostat **

Spill switch

(if used)

(may also be wiring in

the 120-v limit circuit)

**

120-v limit

circuit

120

VAC

GND

Hot

Neu

Control panel enclosure

Combination
gas valve

NOTICE: Line voltage polarity

The hot and neutral power wires
must connect as shown for correct
operation of the burner controls.

Br = brown
Gr = green

Bk = black
Blue = blue

Or = orange
Pur = purple
Gray = gray

Wire color coding

120

factory wiring

VAC

24

factory wiring

VAC

120

field wiring

VAC

24

field wiring

VAC

Wire connector

G3B01

Line switch **

**

Supplied by installer

Red = red
Wh = white
Yel = yellow

Bk

GND (BURNER)

Gn

Yel

24V (GND)

Yel

Gnd

Connect ground wires
to green terminal strip
screws when replacing
a Fenwal control with a
Honeywell S89C.

Verify power supply

1. The burner requires a 120

VAC

/60

HZ

/single-phase power supply. The

current draw will be aproximately 8.0 amps. Protect line with a 10-amp
or 15-amp fuse or breaker.

2. The 120

VAC

power connections to the burner must be connected as

shown in Figure 7. The control is polarity-sensitive, and will not work if
the hot and neutral lines are reversed.

3. Verify that the power supply to the burner is no less than 102

VAC

nor

more than 132

VAC

.