Model G3B Gas burner — Instruction manual

Carlin part number MNG3B Gas Rev. 03/17/09

15

Make fi nal burner adjustments

(continued)

Check combustion using instruments

You must use combustion test instruments. Failure to properly

verify/adjust combustion could allow unsafe operation of the
burner, resulting in severe personal injury, death or substantial
property damage.

Figure 9 Flame signal measurement connections

Insert test probe into vent above appliance to sample fl ue products.

The results should show CO

2

or O

2

as follows:

If the combustion results are outside the range above, and the fi ring

rate of the burner is within 5% of rated input, open or close the air
throttle until the CO

2

(or O

2

) are acceptable.

After

CO

2

(O

2

) tests are completed satisfactorily, measure

fl ue products for carbon monoxide (CO) concentration. The
CO must not exceed 50 ppm adjust to “air free”, or other if
specifi ed by local codes.

Adjust the draft in the appliance so the draft overfi re is about –0.01

inch w.c. and take a fl ue gas sample from the combustion chamber.
If CO

2

is noticeably lower overfi re than in the vent, the appliance has

leaks that must be repaired.

5. Perform checkout procedures • fi ll out certifi cate

(continued)

Check fl ame signal

Electrical shock hazard — Turn off power to burner before

proceeding with setup for fl ame signal measurement.

(See Figure 9.) The HSI is powered with 120 VAC during pre-purge

so a microammeter with a shunt switch must be used to test fl ame
signal or the meter will be destroyed. USE ONLY needle movement-
type meters, not digital meters.

Remove the ignitor lead wire from HSI terminal of the S89C primary

control. Connect a shunt switch and

DC

microammeter between

HSI terminal and the ignitor lead wire. Make sure shunt switch is
closed. Then turn on power to the burner. After the burner fl ame
starts, wait at least 15 seconds, then open shunt switch and read DC
amps (must be at least 0.8 microamps DC).

DO NOT start the burner or adjust the air throttle with the

shunt switch open. The 120 V supply to the HSI will destroy
the microammeter.

Make fi nal burner adjustments

(continued)

Fuel

CO

2

O

2

Minimum

Maximum

Maximum

Minimum

Natural Gas

9.6%

10.8%

4.0%

2.0%

Propane Gas

11.0%

12.5%

4.0%

2.0%