TROUBLESHOOTING GUIDE

PROBLEM

PROBABLE CAUSE

POSSIBLE REMEDY

No power to unit,
No light on display
Motor not running

Not plugged in or circuit breaker
off or tripped

Plug into receptacle.
Reset circuit breaker,
check facility circuit breaker

Main switch damaged

Check main power switch,
replace if damaged

Damaged power cord

Replace cord

Hi-limit safety tripped

Allow unit to cool, hi-limit will
reset automatically, or replace

Unit does not hold temperature Damaged door gasket (metal

trim strip)

Replace gasket

Damaged door latch

Replace defective latch

Temp probe damaged

Replace probe

Door gap, out of alignment

Adjust door hinging and strike

Unit does not heat

Cabinet temp above setpoint
(setpoint too low)

Turn thermostat setpoint up
Check thermometer calibration

Internal wiring error

Call service technician

Damaged relay

Call service technician

Damaged controller

Call service technician

Damaged heating element

Perform ohm reading,
Replace element

Unit overheats

Setpoint too high

Change setpoint

Thermostat damaged

Replace thermostat

Defective hi-limit control

Call service technician

Blower fan failure

Call service technician

Blower motor not running

Damaged fan motor

Replace motor

Blower fan jammed

Find source of fan binding

Relay is “chattering”

Check proper wiring to switch

Repair wiring or replace switch

Takes too long to get to tem-
perature

Improper voltage

Call service technician to verify
that incoming voltage matches
cabinet specifications

NOTE:

The technical content of this manual, including
wiring diagrams, schematics, parts breakdown
illustrations and/or adjustment procedures, is
intended for use ONLY by qualified techni-
cal personnel
.

NOTE:

For warranty service, call Carter-Hoffmann
direct at 800-323-9793 for authorization. We
will dispatch the nearest authorized service
agency.

Advertising
This manual is related to the following products: