Caution, Warning – Carter-Hoffmann PHW1822 User Manual

Page 5

Advertising
background image

5

If necessary, contact a licensed
electrician to install an appropriate

208 volt, 60 Hz, 3063 watt, 15
Amp circuit. NEMA L6-20P plug.


DO NOT use an extension cord.

LOCATION

For proper operation and maximum performance, locate the
unit in an ambient air temperature of 70ºF (21ºC).

Avoid placement in areas near exhaust fans or where there
are active air movements.

For safe operation and maximum performance, locate the
unit at least 2” from any wall or combustible material.

Unit must be on a solid level surface.

LOCATION & INSTALLATION

GROUNDING INSTRUCTIONS

This appliance is equipped with a cord having a grounding wire with
a grounding plug which must be plugged into an outlet that is prop-
erly installed and grounded. In the event of an electrical short cir-
cuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current.

WARNING—Improper use of the grounding can result in a risk
of electric shock.
Consult a qualified electrician or service agent if
the grounding instructions are not completely understood, or if doubt
exists as to whether the appliance is properly grounded.

Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical codes. Failure could
result in personal injury and prop-
erty damage.

Damage to unit due to being
connected to the wrong voltage or
phase is NOT covered by warranty.

T

he ground prong of the power

cord is part of a system designed to
protect you from electric shock in
the event of internal damage.

DO NOT cut off the large round
ground prong or twist a blade to fit
an existing receptacle.

CAUTION:

Electrical Shock Hazard

Unit is not waterproof, to avoid
electrical shock, keep unit from be-
ing submerged in water. Do not
operate if unit has been in contact
with water.

IMPORTANT:

IMPORTANT:
Not under warranty

WARNING:

Risk of personal injury

WARNING:

Risk of personal injury

1. Check for proper voltage and circuit breaker size. Cabi-

net requires

208 volt, 60 Hz, 3063 watt, 15 Amp circuit.

NEMA L6-20P plug.

Verify electrical requirements by

referring to the serial tag on the cabinet.

2. Ensure receptacle is correctly installed and operating

safely. Requires grounded NEMA L6-20R receptacle.

3. Position cabinet on table or counter top. Maintain 2” of

clearance on each side to allow for adequate cooling.

NOTE: The technical content of this manual, including any
wiring diagrams, schematics, parts breakdown illustrations
and/or adjustment procedures, is intended for use ONLY
by qualified technical personnel
.

Sample serial tag
location of electrical
specs