Tension the band until the resistance on the tool handle is constant
(i.e. the band does not slide easily through the buckle). The boot
gasket should be tight against the process pipe under the gasket
protector plate. Verify the band buckle and splice protector plates are
still in place.

Tighten the setscrew to lock the band in place. The setscrew will
dimple the band.

Figure 25

Final Alignment and Securing of Gasket Band

Once the setscrew has been fully tightened, loosen the tensioning tool
and bend the tool and band up and over the buckle. It is not
necessary to cut excess band material (allows for re-tightening of
band if necessary).

Repeat the band installation procedure for the opposite end of the
cover.

Figure 26

Band Termination