Totalizer

Selections under this menu are used to configure the totalizer
functions.

-

Units’ submenu is used to select the units of the display. Currently

these are ‘gal’ (gallons), ‘m

3

(cubic meters), ‘VF Vol Units

(volumetric flow display units), ‘l’ (liters) ‘ft

3

(cubic feet).

-

Lowcut Enable’ turns the lowcut function on or off.

-

Lowcut sets the flow values that will no longer be used for

totalization.

-

Multiplier’ selects the multiplier applied to the displayed totalized

units. Selections of ‘M’ (x 1,000,000), ‘k’ (x 1,000), ‘1’ (x 1) are
available. Note: This selection does not affect the pulse output when
Totalizer’ is selected. Set the pulse output multiplier in the ‘Pulse
setup menu.

-

Reset’ sets the totalizer display to zero.

Wr Protect Mode

When this is ‘Enabled’ no other parameters can be changed. The
user must ‘Disable’ this option before making any menu changes.
Default is ‘Disable’.

10.1.5 Communications

Menu

Ethernet

Option is used to view and set the IP address and Subnet Mask of the
transmitter.

Serial Options

Used for setting up the ‘Baud Rate’ and the serial communications to
‘RS232’ or ‘RS485’.

HART

Settings are used for configuring the protocol when using HART.
Default is for single device addressing.

Reset Comms

Used to re-initialize the communications ports without loosing data
history (as would happed by re-initializing the transmitter). This can
be used to restart acquiring data if, for example, the ethernet cable
was removed from the ethernet port while the StBasic program was
still running.