Important: Always read and follow instructions.

• 21

Troubleshooting

A COATS® Service Technician may ask for informa-

tion to help diagnose service concerns (please contact

COATS directly at 1-800-688-9240 for the Certified

Service Partner nearest you). Conveying this informa-

tion to your service technician prior to servicing can help

to expedite service to your equipment. Although much

of the diagnostic information aids your COATS Service

Technician, several remedies for balancer misfunctions

are available to the operator.

Error Messages - One of the following error mes-

sages, shown in the display windows, may appear

indicating a problem with the balancer.

Note: Always, after receiving an error message, repeat

the procedure to see if the error is eliminated.

Error

Description

E1 Spin up is too slow - Verify power supply

to balancer and motor connection

E2 Spin up time too long - Check Wheel DIA

and power supply - press STOP - EXIT

E3 No rotation signal - Check motor &

encoder function & wiring -press STOP -

EXIT

E4 Wheel rotation direction is reversed -

Disconnect power and correct wiring

E5 Stop time too long - Verify power supply

and motor connection - press STOP - EXIT

E6 Encoder is not connected or has failed -

Disconnect power supply and repair

E9 Wheel coast speed is too slow

E11 User cancelled the operation

E20 Arm scale is out of range
E24 Lower hood to spin
E25 Loose hub nut. Tighten hub nut and respin
E26 CAL ERROR

Err Hod Hood switch is not closed when machine

cycle is started - Lower hood to spin -

Verify hood switch

Err Hub No load condition detected - Verify wheel

mounted properly on the shaft - Check

repeatability

Err Ad No dimension input

Inverter

Error

Inverter Fault-Please Wait …

Error

Description

100, N01, CAL Exceeded 5 degree range

between placement of calibration

weight from outside flange to

inside flange.

100, N02, CAL Calibration wheel is more than

1-ounce out of balance. Calibration

is rejected.

100, N03, CAL Calibration wheel is more than

0.25-ounce but less than 1-ounce

out of balance. Calibration is

stored, but with warning.

Inverter Error - An inverter error occurs when one of

several fault conditions is detected by the inverter; such

as, low line voltage, motor over temperature, motor

overload or motor drive over temperature. The balancer

will not respond to inputs until the fault condition is

corrected. The balancer will clear this error as soon as

possible and indicate that with the following message:

Inverter Fault Cleared. Press Any Icon

Overload Protection - The balancer’s motor is over-

load protected per UL requirements. After 4 to 5 min-

utes the machine automatically resets itself; activating

the fan motor. If this happens, notify your Certified

Service Partner immediately.

Important: Allow the fan to cool the motor for at least

30 minutes before using the balancer so the overload

protection is not tripped again.