Puller Calibration

When using the electronic control system, the Condux Fiber Optic Cable Puller does not need to be calibrated

on a regular basis; however, the calibration should be checked periodically (at least yearly) to ensure that the

calibration has not changed. If the calibration procedures specified below are not possible at the operator’s

location, we recommend returning the unit to Condux International for calibration by the factory. See section

15 for details on returning the puller to Condux International for calibration.

A. vERIFY THE PULLER’S CALIbRATION SETTINgS

1. Set up the puller as if cable were to be pulled, including installation of the capstan (figure 21).

2. Place a pull line around the capstan. The pull strength of the pull line must exceed the 2,000 pound maxi-

mum capacity of the Fiber Optic Cable Puller.

3. Attach the pull line to a load indicator such as a Dillion dynamometer (section 14).

4. Set the electronic control box tension limit according to the load rating on the capstan.

5. Slowly apply pressure to the puller to tighten the pull line. Continue to pull until the relief valve opens. The

value shown on the dynamometer will be the force at which the pressure relief valve is set for this hydraulic

fluid temperature (see next page).

6. Release pressure to the puller.

7. Set the electronic control box tension limit to the desired tension to be verified.

8. Slowly apply pressure to the puller to tighten the pull line. Continue to pull until the electronic control system

stops the puller and the alarm sounds. The value shown on the dynamometer should match the tension

limit set on the electronic control box.

b. HYDRAULIC PRESSURE RELIEF vALvE CALIbRATION

The hydraulic pressure relief valve on the Fiber Optic Cable Puller is calibrated to the following loads.

• Relief Valve:

1,783 lbs. (7,930 N) line tension on the 12" (305 mm) diameter capstan

700 lbs. (3,113 N) line tension on the 30" (762 mm) diameter capstan

428 lbs. (1,903 N) line tension on the 42" (1,067 mm) diameter capstan

If a different load is required, the relief valve can be adjusted with the following procedure. Do not execute

this procedure to verify the calibration (see previous section).

11.

Dynamometer

Fixture

Capstan

Rope (Spec to exceed

pulling capabilities of cable

puller) wrap 3-4 times

Figure 21. Calibration verification Setup