Troubleshooting guide – Condux CableGlider FO Cable Puller User Manual

Page 20

Advertising
background image

20

Troubleshooting Guide

A. PULLER

12.

SOLUTION:

Reverse the connections on one end of the hose

assembly between the foot control valve assembly

and the puller (see section 5.B.2).

• The adjustable flow control knob on foot control

could be limiting movement. Turn flow control knob

counterclockwise until full movement is achieved

(see section 5.C.1).

• Check that the area under the foot control pedal is

clean and free of all obstructions.

• Check adjustable pressure relief valve setting to

ensure that it is not opening prematurely (see sec-

tion 11.B).

• Check the hydraulic power source that the hydraulic

power provided to the puller is the required 2000

to 2500 psi (137-172 bar) of pressure and 6 to 10

gpm (22.7-37.9 lpm) of flow.

• Check system for hydraulic leaks.

• Puller is not properly aligned with the pull line. The

pull line must be placed around the capstan at a slight

angle to the edge of the capstan (see section 7.A).

• The posts on the shaft must line up with the rooves

on the capstan (see section 5.D).

• Apply an anti-seize compound to the ID of the cap-

stan and the OD of the puller shaft.

• Hydraulic pressure is remaining in the hydraulic

lines. Carefully unscrew one of the quick-connect

couplings to relieve the internal pressure. Before

disconnecting the hoses, be sure to cycle the foot

control valve with the power supply off to relieve

any internal pressures.

• Contamination has gotten into the couplings.

Visually inspect couplings; clean and remove any

contamination. Use the supplied dust caps.

PRObLEm:

Capstan does not rotate in the required direction

when the foot pedal is depressed.

Foot control pedal will not depress fully.

Puller is not achieving maximum pulling force or

speed.

Pull line will not stay on the capstan.

Capstan will not go onto the puller shaft.

Hydraulic quick-connect couplings will not go

together.

Advertising