Appendix c, Atex / ce approval – Det-Tronics NTMOS IP66/IP67 H2S Gas Detector User Manual

Page 17

Advertising
background image

2.1

95-8670

15

APPENDIX C

ATEX / CE APPROVAL

NOTE

The NTMOS Gas Detector is designed and approved as a ‘stand alone’ toxic gas detector.

Hazardous Location
ATEX: 0539

FM

APPROVED

®

II

2

G

Ex

d

IIC

T5

Gb

FM09ATEX0063X

T5

(Tamb=

–40°C

to

+65°C)

IP66/IP67 (with hydrophobic filter and sinter guard)

IP63

(without

hydrophobic filter).

EN

Standards:

EN

50270:

2006

EN

60079-0:

2009

EN

60079-1:

2007

EN 60529: 1991+ A1 2000.

IECEx:

Ex

d

IIC

T5

Gb

IECEx

FMG

09.0011X

T5

(Tamb=

–40°C

to

+65°C)

IP66/IP67 (with hydrophobic filter and sinter guard)

IP63

(without

hydrophobic filter).

IEC

Standards:

IEC

60079-0:

2007

IEC 60079-1: 2007

IEC 60529: 2001

Special Conditions for Safe Use (X) / Schedule of Limitations:
• The NTMOS Hydrogen Sulfide Toxic Gas Detector shall be connected directly to a junction box or instrument

suitable for the area of installation to provide protection for the flying leads.

• The NTMOS Hydrogen Sulfide Toxic Gas Detector, when the optional sinter guard is not fitted, meets the impact

test requirements according to the low level risk of mechanical danger. Therefore, when the optional guard is not

fitted, the NTMOS Hydrogen Sulfide Toxic Gas Detector must be located and installed such that the risk of impact

is reduced.

• In order to maintain IP66/IP67 Ingress Protection rating, the detector must be mounted vertically at a maximum

height of 18 inches from surfaces below.

Advertising