Det-Tronics PW9200x Pathwatch IR Gas Detection System User Manual

Page 24

Advertising
background image

If malfunctions cannot be corrected by carefully fol-
lowing the procedures described in this manual, con-
tact the factory for assistance. In many cases, suffi-
cient information to correct the malfunction can be
provided over the telephone. If it is necessary to con-
tact the factory by telephone, it is helpful to have the
operation and maintenance manual accessible and to
obtain the following readings for the service techni-
cian:

Instrument S/N ________________

Options purchased ______________________________

Measure and record the channel voltages under two
conditions:

1. Normal operating conditions

2.

With the receiver window blocked with opaque
material (e.g. cardboard disk).

NORMAL

BLOCKED

RATIO __________ vdc

RATIO __________ vdc

DENOM __________ vdc

DENOM __________ vdc

NUM __________ vdc

NUM __________ vdc

HC alarm Setpoint __________ vdc

Path length __________ feet or __________ meters

Both field and factory service are available from
Detector Electronics. If it becomes necessary to
return an instrument to the factory, extreme care must
be taken in packing the instrument for shipment. The
monitor should be enclosed in a plastic bag, sur-
rounded with at least two inches of foam or shipping
pellets on all sides and shipped in a heavy duty car-
ton. Lack of sufficient cushioning can cause exten-
sive damage to internal components. It is not usually
necessary to return the transmitter and, if carefully
packed, just the receiver housing cover and attached
components can be shipped.

DEVICE REPAIR AND RETURN

Prior to returning devices or components, contact the
nearest local Detector Electronics office so that a
Service Order number can be assigned. A written
statement describing the malfunction must accompa-
ny the returned device or component to expedite find-
ing the cause of the failure.

Pack the unit or component properly. Use sufficient
packing material in addition to an anti-static bag or
aluminum-backed cardboard as protection from elec-
trostatic discharge.

Return all equipment transportation prepaid to the
factory in Minneapolis.

ORDERING INFORMATION

RECOMMENDED SPARE PARTS

Description

Qty Part Number

Level One (highly recommended)

Transmitter lamp (15 watt)

1

102642-001

Filterwheel motor (115 vac)

1

005618-001

One ampere fuse

5

107407-002

Alarm relay, 115 vac

2

102590-001

Desiccant pack

1

102669-001

Test power cable

1

Level Two (Recommended)

Sync demod p.c. board

Single channel

1

005586-001

Dual channel

1

005586-002

AGC/TE cooler p.c. board

1

005583-001

Rear panel p.c. board

Single channel

1

005595-001

Dual channel (standard)

1

005595-002

Dual channel (fast)

1

005595-003

Detector/preamp assembly

1

005580-001

4 to 20 ma p.c. board

Single channel

1

005592-001

Dual channel

1

005592-002

2 inch diameter lens

1

005616-001

For assistance in ordering a system to meet the
needs of a specific application, please contact:

Detector Electronics Corporation
6901 West 110th Street
Minneapolis, Minnesota 55438 USA
Operator: (952) 941-5665 or (800) 765-FIRE
Customer Service: (952) 946-6491
Fax: (952) 829-8750
Web site: www.detronics.com
E-mail: [email protected]