9. Re-install the clamp loop previously removed into the back of the control module housing. Clamp

down all wires previously held, as well as the new yellow/orange/black cable from the light kit. Apply

blue Loctite #242 or equivalent to screw threads.

10. Plug the three (3) plugs back into the EXM control module before installing it back onto the control

module housing on the monitor. Use the four (4) 8-32 screws previously removed from the monitor.

Apply blue Loctite #242 or equivalent to the screw threads. Tighten screws to 8-10 in-lbs.

Warning:

Over tightening screws may result in damage to the control module.