SYSTEM SPECIFICATIONS
Panel Mount Controller

Input power

12/24 VDC (11 VDC to 27 VDC)

RF power output

Meets FCC part 15 requirements for license free operation

Transmitter dimensions

7 5/8” x 3 7/8” x 2 3/8”

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

FCC ID

QT8PTSS2003

Handheld Controller

Input power

2 AA Batteries (Lithium Recommended)

RF power output

Meets FCC part 15 requirements for license free operation

Transmitter dimensions

6” x 3 1/4” x 1 3/8”

Transmitter weight

10 ½ oz.

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

FCC ID

QT8PTSS2003

Receiver

Power requirements

Without Converter Assembly 12VDC (11-14VDC)

With Converter Assembly (11-30VDC) at the controller under

full load

Electrical Load

See Table 7 Below

Control current

0.07 A (12V)

Operating temperature range

-40

o

C to +65

o

C, -40

o

F to +150

o

F

Environmental Rating

NEMA 4

Monitor

Left/Right

Up/Down

Nozzle

Run Current*

1 – 1.5 A @ 200 psi

1 A @ 200 psi

0.5 A

Stall Current*

33.3 A

33.3 A

NA

Current Trip Point*

13 A

10 A

4 A

Shock

30 G’s (55 Hz. @ .2” double amplitude)

Vibration

15.5 G’s (55 Hz. @ .05” double amplitude) continuous operation

Drop Test

The handheld controller must meet operating specifications after drop from 1m height onto

concrete surface.

Environmental

All enclosures have a NEMA 4 rating (must withstand a 1” stream of water at 65 GPM from a

distance to 10ft. for five minutes with no water entering the enclosure).

Table 7: Motor Current Specifications

*All current ratings are at 12V