Chapter 3: technical information, Physical specifications, Technical data – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Panther User Manual

Page 7: Chapter 3, Technical information, Physical specifications 3.2. technical data

Advertising
background image

Gold Panther Installation Guide

MAN-G-PANIG-EC (Ver. 1.000)

|Physical Specifications|

www.elmomc.com

7

Table of Contents

Chapter 3:

Technical Information

3.1. Physical Specifications

Feature

Units

All Types

Weight

g (oz)

300 g (10.6 oz)

Dimension

mm (in)

111 x 76 x 34 (4.37" x 3" x 1.34")

Mounting method

PCB Mounted

3.2. Technical Data

Feature

Units 12/400 16/400 R17/400 R22/400 8/800

12/800

R11/800 R16/800

Minimum supply

voltage

VDC

*For S or T type = 50

For 0 or 1 suffix type = 100

*For S or T type = 95

Nominal supply voltage VDC

325

560 for 400 VAC
680 for 480 VAC

Maximum supply

voltage

VDC

400

780

Maximum continuous

power output

W

Up to 10 kW of continuous qualitative power

Efficiency at rated

power (at nominal

conditions)

%

> 98

Auxiliary supply

voltage option

VDC

18 to 30 VDC (only in S or T type)

Auxiliary power supply

VA

≤5 VA without external loading

≤8 VA with full external loading

Continuous current

limit (Ic) Amplitude

sinusoidal/DC

trapezoidal

commutation

A

12

16

17

22

8

12

11

16

Sinusoidal continuous

RMS current limit (Ic)

A

8.5

11.3

12

15.5

5.7

8.5

7.8

11.3

Peak current limit

A

2 x Ic

No peak

2 x Ic

No peak

*See page 9 for details on the part number. The S or T suffix appears in models where there is a 24 V
control supply. If there is an 0 or 1 suffix, the control power supply operates from the main power.