Auxiliary supply, Product features, Auxiliary supply 3.2.2. product features – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Panther User Manual

Page 8

Advertising
background image

Gold Panther Installation Guide

MAN-G-PANIG-EC (Ver. 1.000)

|Technical Data|

www.elmomc.com

8

Table of Contents

Note on current ratings:

The current ratings of the Gold Panther are given in units of DC

amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS (sinusoidal
commutation) value is the DC value divided by 1.41.

3.2.1.

Auxiliary Supply

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

18 VDC to 30 VDC

Auxiliary supply input power

< 4 VA (this includes the 5 V/200 mA load for the main
encoder only)
< 5.5 VA (this includes the 5 V/400 mA load on the main
encoder and feedback B)

3.2.2.

Product Features

Main Feature

Details

Presence and No.

STO

TTL

PLC Source

Digital Input Option

TTL

6

PLC Source

6

Digital Output Option

TTL

4

PLC Source

4

Analog Input

Differential ±10V/Single Ended

1/1

Feedback

Standard Port A, B, & C

Communication Option

USB

EtherCAT

CAN

RS-232 TTL level

Advertising