Current gain control (cgc) – ElmoMC SimplIQ Analog Servo Amplifiers-Flute Installation User Manual

Page 24

Advertising
background image

Flute Installation Guide

Servo Control Operation

MAN-FLUIG (Ver. 2.301)

www.elmomc.com

24

4.3. Current Gain Control (CGC)

The Flute amplifier is equipped with Current Gain Control (CGC) for improved performance of
low induction motors. Connecting pin J2/5 to J2/4 reduces the gain of the current loop, thus
enabling the use of low inductance motors without the insertion of an additional inductor. The
default (pin J2/5 left open) is high gain.

Shorting this pin to the circuit common pin (J2/4) reduces the proportional gain (P) of the
current loop by approx. 70%.

For permanent selection, a simple short is recommended. For remote selection, the following
scheme should be used.

Figure 5: CFM and CGC Remote Control

The following table should be used for calculating minimum inductance values.

Minimum Inductance for High Gain

Minimum Inductance for Low Gain

5/60

L

Load (millihenry)

> 12*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 4.8*10

-3

* V

supply

(Volt)

10/60

L

Load (millihenry)

> 6*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 2.4*10

-3

* V

supply

(Volt)

15/60

L

Load (millihenry)

> 4*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 1.6*10

-3

* V

supply

(Volt)

25/60

L

Load (millihenry)

> 2.4*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 0.9*10

-3

* V

supply

(Volt)

3/100

L

Load (millihenry)

> 27*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 6.6*10

-3

* V

supply

(Volt)

10/100

L

Load (millihenry)

> 9*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 2.2*10

-3

* V

supply

(Volt)

15/100

L

Load (millihenry)

> 6*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 1.5*10

-3

* V

supply

(Volt)

20/100

L

Load (millihenry)

> 4*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 1.1*10

-3

* V

supply

(Volt)

2/200

L

Load (millihenry)

> 49.5*10

-3

* V

supply

(Volt)

L

Load (millihenry)

> 12*10

-3

* V

supply

(Volt)

6/200

L

Load (millihenry)

> 16.5*10

-3

*V

supply(Volt)

L

Load (millihenry)

> 4*10

-3

* V

supply

(Volt)

10/200

L

Load (millihenry)

> 10*10

-3

*V

supply(Volt)

L

Load (millihenry)

> 2.4

-3

* V

supply

(Volt)

15/200

L

Load (millihenry)

> 6.5*10

-3

*V

supply(Volt)

L

Load (millihenry)

> 1.6

-3

* V

supply

(Volt)

Table 8: Minimum Inductance Values

Advertising