Installing the canopy fixture, Dmx/rdm cable installation, If using belden 9729 for dmx/rdm input – ETC Desire D22 User Manual

Page 5

Advertising
background image

5

Installing the Canopy Fixture

The Canopy D22 Desire Series is installed on to a RACO 232 series 4 x 2-1/8 inch
deep double junction box. The fixture is supplied with a divider to separate the data
network from the line voltage inside the junction box.

DMX/RDM Cable Installation

Step 1:

Terminate DMX/RDM input from the control source to the junction box.

This connection could be Belden 9729 or Category 5.

If using Belden 9729 for DMX/RDM input:

a:

Reference the DMX Cable Preparation for
Screw Termination Setup Guide
for
instructions to prepare and terminate
Belden 9729 for DMX input cable to the
screw terminal connector.

b:

Install the screw terminal connector with
wires terminated to the DMX/RDM Input
receptacle on the termination board.

C A U T I O N :

Separate the line voltage from the data side in the

junction box. Install the voltage barrier provided by

ETC.

Canopy

Installation hook

Junction box
(not provided)

Data/Voltage
divider

Mounting plate
assembly

From a DMX/RDM source

Data – (Black)

Data + (Red)

Belden 9729 (or equivalent) wire
termination to screw connector

4 to 8 = n/c

COM

Advertising