Technical data, Technical data for safety switch ces-ar-c01-ah-sa – EUCHNER CES-AR-C01-AH-SA (Unicode) User Manual

Page 24

Advertising
background image

Operating Instructions Safety Switch CES-AR-C01-AH-SA

24

Technical data

Note:

If a product data sheet is included with the product, the information on the data

sheet applies in case of discrepancies with the operating instructions.

Technical data for safety switch CES-AR-C01-AH-SA

Parameter

Value

Unit

min.

typ.

max.

Housing material

PBT V0 GF30

Dimensions

According to EN 60947-5-2

Weight

0.4

kg

Ambient temperature at U

B

= DC 24 V

- 20

-

+ 55

°C

Storage temperature

- 25

-

+ 70

Degree of protection

IP67

Safety class

III

Degree of contamination

3

Installation position

Any

Connection

M12 plug connector, 8-pin

Operating voltage U

B

(reverse polar-

ity protected, regulated, residual

ripple < 5%)

24 ± 15% (PELV)

V DC

For the approval according to

the following applies

Operation only with UL Class 2 power supply, or equivalent

measures

Current consumption

50

mA

Switching load according to

DC 24 V, class 2

External fuse (operating voltage)

0.25

-

8

A

Safety outputs OA/OB

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage U(OA)/U(OB)

1)

HIGH

U(OA)

U

B

-1.5

-

U

B

V DC

HIGH

U(OB)

LOW

U(OA)/U(OB)

0

1

Switching current per safety output

1

-

400

mA

Utilization category

according to EN IEC 60947-5-2

DC-13 24 V 400 mA

Caution: outputs must be protected with a free-wheeling diode in

case of inductive loads.

Off-state current I

r

≤ 0.25

mA

Monitoring output OUT

1)

p-switching, short circuit-proof

- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

200

mA

Rated insulation voltage U

i

-

-

300

2)

V

Rated impulse withstand voltage U

imp

-

-

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-2

Switching frequency

-

-

1

Hz

Repeat accuracy R

≤ 10

%

EMC protection requirements

In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1

Reliability values acc. to EN ISO 13849-1
Category

4

Performance Level

PL e

PFH

d

2.1 x 10

-9

/ h

3)

Mission time

20

years

1) Values at a switching current of 50 mA without taking into account the cable length.
2) Tested by employers’ liability insurance association up to 75 V.
3) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTF

d

= max. 100 years), the employers’ liability insurance

association certifies a PFH

d

of max. 2.47 x 10

-8

.

Advertising