Changing the approach direction – EUCHNER CES-AR-C01-AH-SA (Unicode) User Manual

Page 7

Advertising
background image

Operating Instructions Safety Switch CES-AR-C01-AH-SA

7

Changing the approach direction

Caution!

Risk of damage to equipment as a result of trapped cables.

Ì

Make sure that the cables are not trapped or torn off when the approach
direction is changed.

The active face of the read head can be adjusted in 5 directions. It is marked by

the red face.
The plug connector can be realigned in 45° steps to change the direction of the

cable outlet (when using elbow connectors).

1. Remove the top part of the mounting base and push the bottom part of the

mounting base off the read head.

2. Unscrew the screws on the fastening bracket.

3. Undo the read head from the fastening bracket and tilt the read head forward

by 90°.

¨

The active face is now pointing downward.

4. Hold the fastening bracket tight and turn the read head by 180°.

5. Re-tighten the screws for the read head on the fastening bracket. Tightening

torque 0.6 Nm.

6. Turn the read head in 90° steps until the desired approach direction is

reached.

Change the alignment of the plug connector if necessary.

7. Push the read head onto the bottom part of the mounting base and re-

assemble the mounting base.

Advertising