Wiring an independent control station – Johnson Systems CS-DMX Series Programmable Stations User Manual

Page 7

Advertising
background image

www.johnsonsystems.com

7

CS-DMX-12

DC POWER SUPPLY COMMON (V-) INPUT
DC POWER SUPPLY POSITIVE (V+) INPUT

COM
V+

DMX OUT

CS-DMX-12

DC POWER SUPPLY COMMON (V-) INPUT
DC POWER SUPPLY POSITIVE (V+) INPUT

COM
V+

DMX OUT

COM
V+
ON
DIM
RST

COM
V+
ON
DIM
RST

COM
V+
ON
DIM
RST

COM
V+
ON
DIM
RST

CS-SA-ENT3B

CS-SA-ENT3B

CS-DMX-12

DC POWER SUPPLY COMMON (V-) INPUT
DC POWER SUPPLY POSITIVE (V+) INPUT

COM
V+

DMX OUT

COM
V+
ON
RST

COM
V+
ON
RST

COM
V+
ON
RST

COM
V+
ON
RST

CS-SA-ENT2B

CS-SA-ENT2B

CS-DMX-12

DC POWER SUPPLY COMMON (V-) INPUT
DC POWER SUPPLY POSITIVE (V+) INPUT

COM
V+

DMX OUT

COM
V+
RST

COM
V+
RST

CS-DMX-12

DMX OUT

DMX IN

Wiring an Independent Control Station

An independent control station requires 2 conductors for V+ and common, and a single DMX

cable for the DMX out connection.

Wiring a Single or Multiple Entrance Control Stations
to a Master Control Station

An entrance control station (Part Numbers: CS-SA-ENT2B and CS-SA-ENT3B) is typically

installed at an entrance location and used to trigger a master control station into the “ON”, “DIM”

or “OFF” state. The entrance station(s) and master station mimic each other when a button

is pressed. Wiring between a single or multiple entrance stations and master station requires

2 conductors for V+ and common, and 3 conductors for the switches (ON, DIM and RST), 1

conductor for each switch function. A single DMX cable is required from the master control station

to the DMX receiving device.

Wiring Two or More Master Control Stations
Together with “Take Control”

When two or more master control stations are controlling the same device (DMX channels), “take

control” is typically required. When a button is pressed on one of the master control stations, it

will automatically “take control” from the other master control stations and put them in the “OFF”

state. Wiring between the master control stations requires 2 conductors for V+ and common, and

1 conductor for reset (RST) “take control”. A DMX cable between the control stations is required,

along with a DMX cable from one of the master control stations to the DMX receiving device.