Battery replacement, Security, User interface – Johnson Systems CS-IPRO Wireless Hand-Held Programmer for CS-DMX Series User Manual

Page 4: Battery replacement security user interface

Advertising
background image

www.johnsonsystems.com

4

Battery Replacement

2 x AA Batteries

Alkaline or Nickel Metal Hydride (NiMh) ONLY!
Ensure batteries are installed as indicated inside the battery compartment.
The combined voltage of the batteries must be greater than 1.9 VDC for the CS-IPRO to power on.

Security

If the SECURITY jumper on the rear of CS-DMX control station is installed in the ENABLED

position, the security KEY set in the CS-IPRO must match the security KEY set in the CS-DMX

control station to make any changes to the DMX channel patch configuration. The SECURITY

jumper is installed in the DISABLED position by factory default. If security is required, it should be

implemented at the time of installation. Refer to SECURITY menu items EDIT KEY, SET KEY and

GET KEY on page 10 for further details.

User Interface

The user interface provides access to all of the configuration menu items. It consists of an LCD

display, four (4) programming switches and a power ON/OFF switch. Within a few minutes most

users will find the menu structure very intuitive and easy to navigate. All configuration settings are

automatically stored into an on-board internal EEPROM.

LCD Display
The LCD display is capable of displaying 2 lines of 8 characters. The LCD backlight automatically

turns on when there is activity and turns off after two (2) minutes of inactivity. The LCD contrast

can be easily adjusted for optimum viewing. Refer to menu item “LCD VIEW ADJUST” on page 8

for further details.

Programming Switches
The MENU UP/DOWN

( )

switches are used for navigating through the various configuration

menu items. They also allow for programming of other specific parameters within a selected

menu. Pressing and holding either switch will speed up the scroll rate, which can be helpful to

speed up the configuration time.
The EXECUTE

( )

switch is normally used to select/enter a menu item, advance forward

within a selected menu item, toggle between parameters within a selected menu item or select

parameters within a menu.
The ESCAPE ( ) switch is normally used to back up within a selected menu item one step at a

time or exit the menu completely.

Power ON/OFF Switch
Press the ON/OFF switch to power on. Press and hold the ON/OFF switch to power off.

The CS-IPRO will automatically power off after 10 minutes of inactivity.