Chapter

3


Output
Image
(cont.)

Zero Stabilize Bit (O:e/3)

Enables module feature to display “0” when Weigh scale is empty.
0 = Disable

1 = Enable

Least Significant Bit (LSD) Flicker Bit (O:e/4)

LSD of weigh value. Does not change when load is applied or if load

is

constant.

Vibration Filter Bit (O:e/5)

Enables vibration filter to cancel out load variation due to vibration of

product weighed.

0 = Disable

1 = Enable

Channel 2 Trim Bit (O:e/6)

Factory set bit to load Channel 2 trim value into module (Not for end user)


Coarse Zero Up Adjust Bit (O:e/7)

Used to increase offset of amplifier to set to range of A/D.


Channel 1 Trim Bit (O:e/8)

Factory set bit to load Channel 1 trim value into module (Not for end user)


Coarse Zero Down Adjust Bit (O:e/12)

Used to decrease offset of amplifier to set to range of A/D.


Clear Tare Bit (O:e/13)

Resets or removes tare value from module. (Used to initially setup module)


Tare Bit (O:e/14)

Sets weigh value to zero.


Channel Toggle Bit (O:e/15)

Used to switch from Channel 1 to Channel 2 when setting up channels.

Channel 1 Scale Value (Integer Word O:e.1)

Value of scale from capacity of load cell for Channel 1.


Channel 1 mV/V Setting (Integer Word O:e.2)

4 digit mV/V setting from load cell mV/V specification.


Channel 1 A/D Trim Setting (Integer Word O:e.3)

Factory set trim value for Channel 1. (Not for end user)


Channel 2 mV/V Setting (Integer Word O:e.4)

4 digit mV/V setting from load cell mV/V specification.


Channel 2 A/D Trim Setting (Integer Word O:e.5)

Factory set trim value for Channel 2. (Not for end user)


A/D Samples Setting (Integer Word O:e.6)

Sets number of samples (for averaging) of weigh value. (0-1000)


Channel 2 Scale Value (Integer Word O:e.7)

Value of scale from capacity of load cell for Channel 2.