The Helman Group 1769 WEIGH SCALE MODULE HM1525 User Manual

Page 20

Advertising
background image

Chapter

5


System
Trouble-
shooting
Guide




HT-400 Sensor Ohm Readings


Green-Black

350

ohms

Red-White

350

ohms

All other color combinations

266 ohms

All

colors

to

Ground

open

Shield

to

Ground open



Electrical Specifications:



Type of input

Strain Gage (350 ohm, 700 ohm)

Input Impedance

10k

Display Resolution

Up to .0025% of full scale

Overall Module Accuracy

.01% of full scale

Module Update Time

10 µsec

Number of Channels

2 (isolated)

A/D Conversion Method

Successive Approximation - 16 bit

Normal Mode Rejection:

(between +/- input)

116DB CMRR

Amplifier Bandwidth

200 kHz

Calibration

Software

Selectable

Isolation:

500 VDC continuous between inputs

and

chassis

ground,

and

between

input

and

backplane

LED indicators

2 LED's for Power and Alarm

Recommended Cable

Strain Gage Cable (Helm part number 6117)

Terminal

Strip

16-pin

removable

Operating Temperatures

0°C to 60°C (32°F to 140°F)

Hazardous Environment
Classification

Class

1

Division 2 Hazardous Environment


















Trim Jumper


Located at Bottom
Left Corner of Module


Black Jumper

Factory Jumper. Removing this
Jumper will cause module to
Become unstable.







Page 5-1