ELECTRICAL SPECIFICATIONS

Temperature

Range

J-type

-346°F~2192°F

-210°C~1200°C

64K ~ 1472K

K-Type

-328°F~2498°F

-200°C~1370°C

74K ~ 1642K

T-type

-328°F~752°F

-200°C~400°C

74K ~ 673K

E-Type

-238°F~1832°F

-150°C~1000°C

124K ~ 1273K

Display

Resolution

J-type

0.1°F<1000°F

0.1°C<550°C

0.1K<824K

1°F≥1000°F

1°C≥550°C

1K≥824K

K-Type

0.1°F<1000°F

0.1°C<750°C

0.1K<1000K

1°F≥1000°F

1°C≥750°C

1K≥1000K

T-type

0.1°F<752°F

0.1°C<400°C

0.1K<673K

N/A

N/A

N/A

E-Type

0.1°F<750°F

0.1°C<400°C

0.1K<673K

1°F≥750°F

1°C≥400°C

1K≥673K

Temperature

Accuracy*

J, K, E

Type

±[0.1% + 1.4˚F(0.8˚C)]
<-148˚F(-100˚C) add 0.2% of reading

T Type

±[0.3% + 2.7˚F(1.5˚C)]
<-148˚F(- 100˚C) add 0.5% of reading

Temperature

Coeffi cient

0.01% of reading 0.1°F per °F(+0.05°C per °C) for

<+64°F (+18°C) or +82°F (+28°C)
[Below -148°F (-100°C): add 0.05% of reading for J,

K, and E-type; and 0.1% of reading for T-type]

Real Time

Clock Tolerance About 1 second per day

Max

Differential

Common Mode

Voltage

1V Maximum voltage difference

(between any pair of inputs)

Temperature

Scale

ITS-90 (International Temperature Scale of 1990)

Standards

N.I.S.T. Monograph 175 revised to ITS-90

* Accuracy is specified for ambient temperatures between 64°F and

82°F (18°C and 28°C) for a period of 1 year. The above specifications

do not include thermocouple error.