Multiserver 5000, Screen display messages, Message message type explanation – Black Box 5000 User Manual

Page 230

Advertising
background image

Multiserver 5000

228

LOCAL DIGITAL

Diagnostic

The RD signal is being internally looped to the

LOOP LINK #

ci

TD signal and transmitted onto the VF line.

LOCAL DTE LOOP

Diagnostic

The TD signal is being internally looped to the

LINK #

ci

RD signal.

LOCAL FOX

Diagnostic

The port is in a local fox loopback test.

ni LOCAL LINK RESTART ci

Event

Node ni on link ci has been restarted.

ni LOCAL SYSTEM RESET

Alarm

The local Multiserver unit has been reset.

LOCAL TEST, ECHO INPUT

Diagnostic

The port has been placed into a local echo loopback
test.

LOCAL TX/RX TEST

Diagnostic

The TX test pattern generator and RX error

PATTERN LINK #

ci

detector have both been activated.

LOCAL VF LOOP LINK

Diagnostic

The local receiver VF signal is being routed into the
modem, looped out through the local transmitter,
and amplified through a variable gain stage.

LOCAL 1004 HZ

Diagnostic

The local modem is transmitting a test tone

TONE LINK #

ci

of 1004 Hz over the telephone line.

LOCKED PARAMETER

Event

This parameter is locked out by the hardware
configuration.

LOGGING REPORT,

Event

Command Facility is not available because it is

TRY LATER

being used to send reports.

MODULE NOT OPERATIONAL

Info

LAN module is installed but not operational.

<NO ANSWER>

Dialog

Indicates that no answer was received from the
async destination port. Causes include the
following:

• Remote port did not respond to connection

protocol.

• No response was received within the call

timeout period from the remote Multiserver,
although the ports are known by the local
Multiserver.

• Call inhibit is enabled (on).
• DTR = low = OOS.

ni NO ANSWER LINK ci

Event

The calling process has discontinued due to the
absence of an answer tone on a local dial line.

Screen Display Messages

Message

Message Type

Explanation