Wiring the device modules

Communication modules

8

l

69

EDK94ASH24 DE/EN/FR/ES/IT 4.1

DIP switch

Pos.

Description

0

Addressing of the bus node

Baud

CAN Address

O

N

c

d

b

a

64

32

16

8

4

2

1

A

9400CAN003

Fig. 8−3

Arrangement and labelling of the DIP switches

For the DIP switches that are placed at the front

ƒ

the node address (labelling "1" ... "64") and

ƒ

baud rate (labelling "a" ... "d")

can be set.

)

Note!

If all address switches adopt the "OFF" position when the basic device is
switched on, the configurations of codes C00350 (nodes address) and C00351
(baud rate) apply.
Switch the voltage supply of the basic device off and then on again to activate
altered settings.

Setting the node address

The node address of the drive is calculated from the sum of all address switches in the "ON"
position.

Setting the baud rate

d

c

b

a

Baud rate

OFF

ON

ON

OFF

10 kbit/s

OFF

ON

OFF

ON

20 kbit/s

OFF

OFF

ON

ON

50 kbit/s

OFF

OFF

ON

OFF

125 kBit/s

OFF

OFF

OFF

ON

250 kbit/s

OFF

OFF

OFF

OFF

500 kbit/s

ON

ON

ON

OFF

800 kbit/s

OFF

ON

OFF

OFF

1000 kbit/s

OFF

ON

ON

ON

Auto baud

Displays

Pos.

Colour

Condition

Description

MS

Green

On

Communication module is supplied with voltage.

DE

Red

On

Communication module is not accepted by the standard device
(see notes given in the documentation for the standard device).

BS

Green

Signalling according
to DR303−3

CANopen state ("Z")

BE

Red

CANopen error ("F")