SECTION 3 - Reset Button & XML

3.2.0

3.3.0

© Copyright 2008

DN IS-IPPC101.1

® Registered trademark MAMAC SYSTEMS, Inc.

20 of 20

Reset Button:

If the user misplaces the appliance

IP address or forgets the password, the

Reset

is designed as a

Back Door

. If any of the above happens, press and hold the reset button

for more than

20 seconds until the heartbeat light stops pulsing; release the switch. The Maverick

IP Address, User Name, Password, Input, Output and Logging configuration will revert back to
Factory Defaults.

XML:

The appliance has XML embedded with formatted input and output data. Each data field has

an XML tag defined. To view all XML tags, connect to the Maverick with any browser and then in
the address bar of the browser enter the following:

Appliance_IP/mav.xml

. As an example, if

the appliance is set up with the default IP to review XML tag page enter

192.168.1.10/mav.xml

in the browser address bar and the Maverick will serve up the XML TAG page as seen in fig. 8. For
additional information on XML, please review TI IP XML.

<?xml version="1.0" encoding="ASCII" ?>

-

<

Maverick

xmlns

="

http://mamacsys.com/mav

">

<

NodeID

>

MAMAC3

</

NodeID

>

<

CurrentTime

>

13:31:25

</

CurrentTime

>

<

CurrentDate

>

September 26, 2008

</

CurrentDate

>

-

<

Sensor Channel

="

1

">

<

SensorName

>

Boiler Temp

</

SensorName

>

<

SensorValue

>

100.0

</

SensorValue

>

<

SensorUnits

>

Deg F

</

SensorUnits

>

<

SensorAlert

>

Normal

</

SensorAlert

>

</

Sensor

>

-

<

Sensor Channel

="

2

">

<

SensorName

>

Humidity

</

SensorName

>

<

SensorValue

>

26.3

</

SensorValue

>

<

SensorUnits

>

%rh

</

SensorUnits

>

<

SensorAlert

>

Normal

</

SensorAlert

>

</

Sensor

>

-

<

Sensor Channel

="

3

">

<

SensorName

>

Heat

</

SensorName

>

<

SensorValue

>

83.8

</

SensorValue

>

<

SensorUnits

>

Deg F

</

SensorUnits

>

<

SensorAlert

>

Normal

</

SensorAlert

>

</

Sensor

>

-

<

Sensor Channel

="

4

">

<

SensorName

>

Heat - Unoccupied

</

SensorName

>

<

SensorValue

>

83.7

</

SensorValue

>

<

SensorUnits>

Deg F

</

SensorUnits

>

<

SensorAlert

>

Normal

</

SensorAlert

>

</

Sensor

>

-

<

Output Channel

="

5

">

<

OutputName

>

Occupied Control

</

OutputName

>

<

OutputValue

>

Off

</

OutputValue

>

<

OutputControl

>

Automatic

</

OutputControl

>

</

Output

>

-

<

Output Channel

="

6

">

<

OutputName

>

None

</

OutputName

>

<

OutputValue

>

Off

</

OutputValue

>

<

OutputControl

>

Automatic

</

OutputControl

>

</

Output

>

-

<

Output Channel

="

7

">

<

OutputName

>

Heat

</

OutputName

>

<

OutputValue

>

Off

</

OutputValue

>

<

OutputControl

>

Manual

</

OutputControl

>

</

Output

>

-

<

Output Channel

="

8

">

<

OutputName

>

Heat - Unoccupied

</

OutputName

>

<

OutputValue

>

Off

</

OutputValue

>

<

OutputControl

>

Manual

</

OutputControl

>

</

Output

>

</

Maverick

>

Figure 8