Mp750si installation - connecting to the tank, Green tube connection – Purenex Multipure Aqua RO System User Manual

Page 11

Advertising
background image

Step 33

Insert the other end of the clear tube to the 1/4” tee connection at the

tank. The tubing must be fully inserted into the tee. The 1/4” tubing

should be inserted about 5/8”. Push the tubing through the small hole

in the tee until you feel resistance. At this point, the tubing is not fully

inserted. Then push firmly until the tubing is inserted as ffar as it will

go.

MP750SI Installation - Connecting to the Tank

Step 34

Drape the green tube connected to the adapta-valve (previously

installed - see page 6 & 10) over to the "IN" side of the RO Pre-

Filter module, leaving a gentle curve in the tubing. DO NOT

SHORTEN THE GREEN TUBE. You will need the full length of the

green tube for flushing the MP750SI Final Filter for future filter

changes.

Step 35

Insert the green tube into the 1/4” connector on the “IN” side of

the RO Pre-filter module. The tubing must be fully inserted in the

connector. The 1/4” tubing should be inserted about 5/8”. Push

the tubing through the small hole in the connector until you feel

resistance. At this point, the tubing is not fully inserted. Then push

firmly until the tubing is inserted as far as it will go.

Flush the RO Module Pre-Filters

Step 36

Insert remaining clear tubing into ¼" connector on "OUT" side of the RO Pre-Filter module.

Drape the other end of the clear tubing up to the sink drain, or to a large bucket.

Step 37

To flush the RO pre-filters, turn on the cold water supply by turning the handle of the valve

counter-clockwise.

Step 38

Allow the water to run through to waste for approximately 5 minutes. Then, Shut off the water

at the valve by turning the handle clockwise until it stops.

Step 39

Disconnect the clear tubing from the "OUT" side port on the RO

Pre-filter module. To disconnect the tubing, first ensure that the

system is depressurized. Then, push in the collet against the face

of the fitting. With the collet held in this position, the tubing can

be removed. The fitting can then be reused.

NOTE:

Retain the clear tubing for flushing the RO pre-filters in the future.

Step 40

Attach the green tubing from the automatic shut-off valve (Item #22) to the “out” connec-

tor of the RO Pre-filter module. The tubing must be fully inserted in the connector. The 1/4”

tubing should be inserted about 5/8”. Push the tubing through the small hole in the connector

until you feel resistance. At this point, the tubing is not fully inserted. Then push firmly until

the tubing is inserted as far as it will go.

Green Tube Connection

11

IN Connector

OUTConnector