NOTE:

Check air pressure when tank is empty

Step

1

Using a digital air gauge, check the air pressure in the tank. You

should always have between 5-7 psi. If you have more than 7 psi,

release air and recheck. If you have less than 5 psi, add air, air can

be added with a bicycle pump.

Step

2

Your unit comes with a stand for your storage tank to sit on if you

need to turn the unit on its side.

Step

3

This allows for air flow under tank keeping moisture and standing

water from rusting on the bottom of your tank which would void

your warranty.