Operational Parameters

Operating Temperatures:

Maximum 100ºF (37.8ºC)

Minimum 40ºF (4.4ºC)

Operating Pressure:

Maximum 100 psi (7.43 g/cm2)

Minimum 40 psi (2.8 kg/cm2)

pH Parameters:

Maximum 11

Minimum 3

Iron:

Maximum 0.2 ppm

TDS (Total Dissolved Solids) < 1800 ppm

Turbidity:

<5NTU

Hardness:

Recommended hardness not to exceed 10 grains per gallon, or 171 mg/L of

hardness as CaCO3. System will operate with hardness over 10 grains but the

membrane life may be shortened. Addition of a water softener may lengthen

the membrane life.

Note:

The operating pressure in your home should be tested over a 24 hour period

to attain the maximum pressure. If it is above 100 psi then a pressure regu-

lator will be required.

Note:

Reverse Osmosis water should not be run through copper tubing as the purity

of the water will leach copper and cause an objectionable taste in water and

cause pin holes to form in tubing. Be sure to follow any state or local regula-

tions

Contents of Reverse Osmosis System

5 Stage RO System has:

1 Tank - White

1 sediment filter

1 RO Membrane - White

2 pre-filters, 5 micron

1 Parts Bag

1 MP750 post filter

1 Faucet Bag

1 bracket

1 Manual

1 hand tool

1 Nitrate/Nitrite test strip

If any of the items are missing, please contact Multipure

prior to installing.

Tools Recommended for Installation

1 1/4” Hole saw bit for faucet opening

Round knock-out punch for Stainless Steel sinks, 1/2” and 1 1/4”

Adjustable Wrench

Sharp Knife

1/2” - 5/8” Open end wrenches

Phillips screw driver

Needle nose pliers - Adjustable Pliers

Electric Drill

1/8”, 1/4”, 7/16” and 1” Drill bits

SEE PAGE 21 FOR AN INSTALLATION OVERVIEW AND PARTS LIST.

Do not use with water that is microbiologically unsafe or of unknown quality, without adequate

disinfection before or after the system. Systems certified for cyst reduction may be used on dis-

infected waters that may contain filterable cysts.