Step 15 Gather the pieces of the drain saddle (#30)

1 Black compression nut

1 Semi-circle bracket with opening

2 Screws

1 Foam washer/gasket

2 Nuts for screws

1 Semi-circle bracket

Step 16

The small square black foam gasket with a circle cut out of the mid-

dle must be applied to the inside of the drain saddle. Remove sticky

tape backing and stick to the drain saddle as shown.

Step 17

Drill a 1/4” hole through the drain pipe at least 1 1/2” above the nut

of the P-trap to allow for the removal of the P-trap, if necessary.

Assemble the drain saddle around the drain pipe. Position the drain

saddle over the drilled hole in pipe. Insert screw driver into pipe.

Using Phillips screw driver, tighten screws evenly and securely on

both sides of the drain saddle. Attach black compression nut, but do

not tighten at this time. The black tubing will be installed later.

CAUTION:

Do not over tighten the screws. It may crack the drain saddle.

Drain Saddle Installation

Tank Valve Installation -

Item #21 on page 21

Step 18

Teflon tape must be applied on the fitting on the top of the tank in a clock-

wise direction. Wrap (4 - 7 turns) around the male pipe threads (MPT) on

the Stainless Steel fitting on top of the tank.

Step 19

Connect the shut-off valve (#21) (supplied in the parts bag) to the threaded

fitting on the top of tank.

7

Tank fitting

Shut-off Valve

Tubing Connections

Note: Do not cut tubes until you get to those steps. Remove caps, if any, from tubes before

cutting tubes. Use wire cutters or sharp knife to make straight square cut. Do not use scis-

sors.

Clear Tube Connection

Step 20

Cut 4"-6" from the clear ¼" tubing. Insert the end of this small sec

tion of tubing into the shut-off valve previously connected to the tank.

Insert the other end of the tubing into the middle port of the ¼" x ¼"

x ¼" tee connector (MC445).

20a The tubing must be fully inserted in the connector fitting; it is recom-

mended that you measure and mark the end of the tubing that you are

inserting in the fitting to assure that it is inserted as far as it will go.

The 1/4” tubing should be inserted about 5/8”. Push the tubing

through the small hole in the connector until you feel resistance. At

this point, the tubing is not fully inserted. Then push firmly until the

tubing is inserted as far as it will go.

Instructions for installing the

remaining clear tubing can be

found on page 10, step 32.