PAGE 26 — MAYCO LS-60TD PUMP — OPERATION AND PARTS MANUAL — REV. #4 (09/15/11)

REAR STABILIZER STAND

To reduce excessive vibration and rocking of the pump, set
the rear stabilizers as follows:

15. Locate both the left and right rear stabilizer stands

(Figure 16).

16. Remove the

cotter pin from the handle tee bolt eye,

and then

pull the handle tee to release the stabilizer

stand (Figure 17).

17. Position both rear stabilizers stands on firm (not loose)

level ground (Figure 18).

18. Align the hole on the stabilizer stand with the hole on

the frame body and

insert handle tee bolt.

19. Insert the cotter pin into handle tee bolt eye to lock the

stabilizer stand.

LS-60TD PUMP — INSPECTION

14. If the hydraulic oil level is low, remove the cap just above

the oil level sight glass (Figure 14) and add the correct
amount of hydraulic oil to bring the hydraulic oil level to
a normal safe operating level. (Use Shell oil Tellus 68 or
Mobil oil DFE26).

Figure 14. Hydraulic Oil Filler Hole

Figure 16. Locatiing Rear Stabilizer Stands

Figure 17. Rear Stablizer Stand

Figure 18. Rear Stablizer Stand Deployment

15. Check the oil level in the

lubrication box. If low, fill

with up to 3 gallons of SAE #30 motor oil (Figure 15).
The oil level must be checked daily. The lubrication box
should be serviced as described in the maintenance
section.

Figure 15. Filling the Lubrication Box