3. To start the engine, insert the key (Figure 20) into the

ignition switch and turn the key to the ON position.

Figure 19. Emergency Stop Switch

Figure 20. Ignition Switch

Figure 21. Status Indicator Lights

LS-60TD PUMP — START-UP PROCEDURE

DO NOT attempt to operate this concrete pump until
the Safety, General Information and Inspection sections
have been read and understood.

STARTING PROCEDURE

If the Emergency Stop switch is in the
CLOSED position (stop), engine will not start.
To start the engine, make sure the Emergency
Stop switch is in the OPEN position (fully
extended).

A. Turn the key to the START position and listen for

the engine to start.

B. In warm weather let engine warm-up for 5 minutes.

In cold weather let engine warm-up for 10 minutes.

C. The

Oil Pressure and Battery indicator lights

(Figure 21) should be OFF.

If any of the status indicator lights
referenced in the ignition section
(step 4) are ON, turn off the
engine. DO NOT continue to run
the engine.

WARNING - GENERAL SAFETY GUIDELINES

4. Observe that the

Battery and Oil Pressure status

indicator lights are ON (Figure 21).

1. Place all switches on the Control Box in the OFF position.

2. Locate the Emergency Stop Switch (Figure 19) on the

Hydraulic Pump Control Box. Turn the Emergency Stop
switch counter-clockwise (open). This will allow the
engine to start.

Figure 22. Cylinder Stroke

Control Switch (Automatic)

5. Turn the

Cylinder Stroke Control switch (Figure 22) to

the AUTOMATIC position.

Figure 23. Pumping Control Switch (On)

6. Place the

Pumping Control Switch to the ON position

(Figure 23) for normal pumping operation. Place the
switch in the REM. position for remote control operation
of the LS-60TD pump.