Maintenance – Multiquip LT12DAB User Manual

Page 33

Advertising
background image

LT12Dab LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #0 (06/03/11) — page 33

6. Route the upper mast cable through the center mast

pulley and connect the free end of the cable to the

lower mast ankle shackle. Route the center mast

cable through the lower mast pulley and connect the

free end of the cable to the hand winch at the bottom

of the lower mast.

7. Raise, extend, retract and lower the mast several times

to verify correct operation.

STORage

For storage for over 30 days, the following is required:

„

Fill the fuel tank completely. Treat with fuel stabilizer if

necessary.

„

Completely drain oil from the crankcase and refill if

necessary with fresh oil.

„

Clean the entire light tower.

„

Disconnect the negative terminals of the battery and

cover it, or remove and store it separately.

„

If the ambient temperature is expected to drop below

0°C, add antifreeze to the radiator.

„

Cover the light tower and store in a clean, dry place away

from children and unauthorized personnel.

MaintenanCe

RemOvaL FROm LOng TeRm STORage

If light tower is going to be used again after long term

storage, perform the following.

„

Apply oil to the engine valve and rocker arms, and

examine the operating condition of the valves.

„

Change the oil in engine oil pan.

„

Replace all the filters.

„

Flush the inside of the cooling system.

„

Drain the water from the fuel tank and bleed the air from

the fuel system.

„

If the engine has not been started for more than one

year, contact your Lombardini distributor to have engine

overhauled.

Advertising