Safety infOrMatiOn

eLeCTRICaL SaFeTY

DangeR

„

The electrical voltage required to operate the generator

can cause severe injury or even death through physical

contact with live circuits. Turn generator and all circuit

breakers

OFF before performing maintenance on the

generator.

„

neveR insert any objects into the output

receptacles during operation. This is

extremely dangerous. The possibility exists

of

electrical shock, electrocution or

death.

„

neveR operate light tower

or handle any electrical

equipment while standing in

water, while barefoot, while

hands are wet or in the rain.

A dangerous

electrical

shock could occur, causing

severe bodily harm or

even death.

„

aLWaYS make sure the area

above the light tower is open

and clear of overhead power

lines and other obstructions.

The tower extends in excess

of 30 feet (9 meters). Contact

with overhead power

lines or other obstructions

could result in equipment

damage,

electrical shock,

electrocution and even

death.

„

Similar to boom equipment

, light tower may become

energized with high voltage.

DO nOT operate the light

tower within a radial distance of 17 feet from high voltage

power lines. If light tower becomes energized with high

voltage, contact with the equipment could result in

electrocution.

„

Backfeed to a utility system can cause

electrocution

and/or property damage.

neveR connect the generator

to a building’s electrical system without a transfer switch

or other approved device. All installations

should be performed by a

licensed

electrician in accordance with all

applicable laws and electrical codes.

Failure to do so could result in electrical

shock or burn, causing

serious injury

or even death.

power Cord/Cable Safety

DangeR

„

neveR let power cords or cables lay in water.

„

neveR use damaged or worn cables or cords when

connecting equipment to generator. Inspect for cuts in

the insulation.

„

neveR grab or touch a live power

cord or cable with wet hands. The

possibility exists of

electrical shock,

electrocution or death.

„

Make sure power cables are securely connected.

Incorrect connections may cause electrical shock and

damage to the light tower.

NOTICE

„

aLWaYS make certain that proper power or extension

cord has been selected for the job.

grounding Safety

DangeR

„

The light tower is equipped with a ground terminal for

your protection.

aLWaYS complete the grounding path

from the light tower to an extrnal grounding source.

„

aLWaYS make sure that electrical circuits are properly

grounded to a suitable earth ground (ground rod) per

the National Electrical Code (NEC) and local codes

before operating generator.

Severe injury or death by

electrocution can result from operating an ungrounded

generator.

„

neveR use gas piping as an electrical ground.