Specifications

Stabilization

Time

< 10 seconds

Integration

Time

Minimum: 1 second

Maximum: 100 hours minus 1 second

Display

Measure-

ment

Ranges

Three level ranges depending on the microphone

sensitivity with manual setting.

M2230 @ sensitivity = 42 mV/Pa

LOW, lower level range: 0 - 100 dBSPL

»

MID, mid-level range: 20 - 120 dBSPL

»

HIGH, upper level range: 40 - 140 dBSPL

»

M2211 @ sensitivity = 20 mV/Pa

LOW, lower level range: 10 - 110 dBSPL

»

MID, mid-level range: 30 - 130 dBSPL

»

HIGH, upper level range: 50 - 150 dBSPL

»

M2215 @ sensitivity = 8 mV/Pa

LOW, lower level range: 20 - 120 dBSPL

»

MID, mid-level range: 40 - 140 dBSPL

»

HIGH, upper level range: 60 - 160 dBSPL

»

M4260 @ sensitivity = 26 mV/Pa

LOW, lower level range: 10 - 110 dBSPL

»

MID, mid-level range: 30 - 130 dBSPL

»

HIGH, upper level range: 50 - 150 dBSPL

»

Residual

noise in [dB]

@ S =

42 mV/Pa

of XL2

without

measure-

ment

microphone

Frequency weighting A

Level range

Leq

Lpeak

LOW

4

17

MID

18

31

HIGH

43

55

Frequency weighting C

Level range

Leq

Lpeak

LOW

3

16

MID

17

30

HIGH

41

55

Frequency weighting Z

Level range

Leq

Lpeak

LOW

7

20

MID

21

34

HIGH

46

58

Advertising