Model 530 operating instructions, Power and measure transmitter mode, Read mode – Practical Instrument Electronics 530 User Manual

Page 6

Advertising
background image

Model 530 Operating Instructions

Power and Measure Transmitter Mode

Transmitter Input

(Sensor)

(Process Signal)

(Simulated Input)

Receiver

Power Supply

0 to 60 VDC

Typical

2-Wire

Transmitter

+ IN -

REF +OUT-

The Model 530 supplies 24 Volts to the transmitter and displays the output in mA or % on the Model 530 display. If the Model 530’s
HART

®

protocol mode is selected, an internal 250 Ω load resistor is connected in series with the output as specified for proper

communication by HART devices. This eliminates the requirement of connecting a separate 250 Ω load resistor in the field as
indicated in field hookup diagrams of HART

®

enabled devices.

Read

Mode

Transmitter Input

(Sensor)

(Process Signal)

(Simulated Input)

Receiver

Power Supply

0 to 60 VDC

Typical

2-Wire

Transmitter

+ IN -

REF +OUT-

The Model 530 can read loop currents from 0-24 mA. The Model 530 limits current in read mode to less than 24 mA to protect the
devices in the loop from over voltage or over current conditions.