Distributor dr100 with tripod assembly procedure – Retsch ZM 200 User Manual

Page 24

Advertising
background image

08.02.2012

Retsch GmbH

24

0003

Distributor DR100 with tripod

1

2

3

4

5

6

7

8

DR100

9

10

11

12

13

14

The distributor of type DR 100 allows larger volumes with a
grain size <8mm to be fed in evenly via the filling hopper of
the ZM200.

The distribution of the feed material is regulated
proportionally via an interface cable in dependence on the
ZM200's motor loading. This ensures that the ZM200's
motor is not overloaded. Manual adjustments are no longer
required.

The ZM200 and the DR100 each require a power socket with
the same phase position to supply the appropriate voltage
and frequency, see the data plates on the devices. It is best
to connect both devices to a multi-distributor power socket.
No further devices should be connected to this distributor
socket.

Assembly procedure

Take the supplied tripod apart into its single parts

Apply a slotted screwdriver to the indentations in the

housing and remove plastic plug 1

Insert tripod rod 2 vertically, screw in and tighten with

an open-jaw spanner size 19

Press the neck of sleeve 3 into the plastic housing, install

washer 4 and tighten with an Inbuss key size 2.5, the pin in

the washer must be seated on the right-hand side

Remove transport lock 5 underneath the DR100 (arrow)
Unscrew the 2 rear rubber feet 6 on the DR100
Fix retainer 8 to the DR100 with screws and washers 7

using the boreholes in the rear where rubber feet 6 have
been removed and the longitudinal holes in retainer 8.
Precise positioning is left until the end.

Place the DR100 with retainer onto the ZM200's tripod
Align the DR100 duct over the ZM200's filling hopper
Tighten toggle screw 9
Turn switch 10 on the DR100 to "standard"
Connect the DR100 at 11 and ZM200 at 12 with the

connecting cable

See the DR100 operating instructions for further operation
of the DR100.

Switch the DR100 and ZM200 on, pictogram 13 appears
on the left of the ZM200's display. The DR100 has been
automatically recognised and the opening mechanism of
the housing cover is switched off, this is displayed by
pictogram 14. This ensures that the housing cover does
not impact against the DR100. Move the DR100 to the
side before opening the housing cover.

The DR100 can be moved aside by undoing toggle screw 9,
after which the filling hopper and cover of the ZM200 are
easily accessible.

Advertising