PT2E-1140

② Zero adjustment impossible

Zero adjustment impossible

Yes

Yes

Zero adjustment mode
with fresh air supplied?

No

Carry out zero adjustment
while supplying the fresh air.

No


Is voltage between TP6(+) and
TPO(-) within -120mV ∼ +120mV?

Sensor deterioration.
Since the sensor must be
replaced, contact our local
agent or RIKEN KEIKI.

Yes

There may be an abnormality in
the electric circuit.
Turn OFF the power supply to
this unit and contact our local
agent or RIKEN KEIKI.

30