CAUTION! DISCONNECT THE LIGHT FROM THE POWER
SUPPLY BEFORE ATTEMPTING ANY OF THE
ELECTRICAL CHECKS MENTIONED BELOW.

PROBLEM POSSIBLE

CAUSE

SOLUTION

No light from light head

Light head is on OFF
position

Turn on the ON/OFF switch to
ON position

No light from light head, when
ON/OFF switch is ON

Bulb has not been
installed or it has burned
out

Refer to bulb replacement
procedure in the manual

Fuse is blown

Inspect / replace the fuse
following the fuse replacement
procedure

No power to the
transformer box

Check for facility power to the
transformer box

Transformer

is

malfunctioning

Check for 14 V AC output at
the transformer when it is
under load.

Incorrect bulb installed

Install correct bulb

Bulb burns out quickly

Incorrect bulb installed in
the light head

Install correct bulb

Light output is irregular in its
shape or intensity

Incorrect bulb installed in
the light head

Install correct bulb

Bulb/reflector is not
seated in its holder
correctly

Adjust the bulb/reflector so it
seats in the holder properly.

No light from light head even
when the bulb and fuse are in
good condition, light head
flashes intermittently when light
head or arms are moved

Circuit or wiring problem
within transformer, arm
assemblies or other part
of lighting system

Check all wiring connections. If
problem cannot be repaired,
call Sunnex Customer Service