Installation, Factory built chimney, Masonry chimney – Regency Classic F1100 Small Wood Stove User Manual

Page 12: Masonry fireplace

Advertising
background image

Regency Freestanding Woodstove

12

FACTORY

BUILT CHIMNEY

When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the
ceiling support package or wall pass-through and "T" section package, fi restops (where needed), insulation shield, roof fl ashing, chimney cap, etc.
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other
obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629,
Standard for 650

0

C Factory-Built Chimneys.

MASONRY

CHIMNEY

Ensure that a masonry chimney meets the mini-
mum standards of the National Fire Protection
Association (NFPA) by having it inspected by
a professional. Make sure there are no cracks,
loose mortar or other signs of deterioration and
blockage. Have the chimney cleaned before
the stove is installed and operated. When
connecting the stove through a combustible
wall to a masonry chimney, special methods
are needed.

Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.

MASONRY

FIREPLACE

There are listed kits available to connect a stove
to a masonry fi replace. The kit is an adapter
that is installed at the location of the fi replace
damper. The existing damper may have to be
removed to allow installation.

Ensure that an effective vapour barrier at the
location where the chimney or other component
penetrates to the exterior of the structure.

Liner

Listed

When referencing installation or connec-
tion to masonry fi replaces or chimneys, the
masonry construction must or shall be code
complying.

When referencing installation or connec-
tion to masonry fi replaces or chimneys, the
masonry construction must or shall be code
complying.