Installation – Regency Classic F1100 Small Wood Stove User Manual

Page 9

Advertising
background image

Regency Freestanding Woodstove

9

Minimum Alcove Clearance to Combustible Materials

The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height - 84"

Maximum depth of alcove - 36"

Minimum Overall Width (X) of Floor
Protector
for all installations:

Small Stove

F1100S

36"

Large Stove

F3100L

40"

INSTALLATION

*The rear clearance to combustibles is less than 6" (152mm), for corner installations the rear corners may be angled to take advantage of the

closer clearances.

Floor Protection

A combustible fl oor must be protected by a non-combustible material (like tile,
concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extend-
ing beneath the heater and a minimum of 6" from each side and minimum
16" from the front face of the stove and minimum 6" (or the rear clearance to
combustibles whichever is smaller) from the rear of the stove.

NOTE: In Canada, fl oor protection must extend 18" to the front and 8" to each side of the stove.

From

From Flue

Min.

Min.Hearth

Unit

Unit

Center-line

Width

to Rear Wall

G

H

I

J

K

L

Small F1100S

with Airmate

11" 7"

23" 13.5"

46"

39"

with Rear Defl ector

13" 5"

25" 11.5"

50"

37"

Large F3100L

with Airmate

16" 9.5"

30" 16"

60"

46.5"

with Rear Defl ector (not approved for Alcove)

Minimum Overall Depth (Y) of Floor Protector

Residential

Residential Mobile Home Alcove

Unit "C" Vent

Close Clearance Close Clearance

Y

Z Y Z Y Z Y

Z

Small F1100S

with Airmate

38" 6"

37"*

5"

38"

6"

38" 6"

with Rear Defl ector

38" 6"

37"*

5"

37"*

5"

37"* 5"

Large F3100L

with Airmate

43" 6"

43"

6"

43"

6"

43" 6"

with Rear Defl ector

43" 6"

43"

6"

43"

6"

n/a n/a