Safety label, Caution, Copy of safety label for f3100l – Regency Classic F1100 Small Wood Stove User Manual

Page 5: Da te of manuf acture, Jan feb mar apr ma y jun jul aug sept oct nov dec

Advertising
background image

Regency Freestanding Woodstove

5

This is a copy of the label that accompanies
each Regency Large Freestanding Woodstove
(F3100L).

We have printed a copy of the contents here
for your review.

SAFETY LABEL

NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.

UNITED STATES ENVIRONMENTAL

PROTECTION AGENCY

F3100L WITH

AIRMATE SHIELD

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

F3100L

WITH AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

SIDEWALL

A 460 mm / 18 in D 810 mm / 32 in

BACKWALL B 305 mm / 12 in E 470 mm / 18.5in
CORNER

C 215 mm / 8.5 in F 560 mm / 22 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 460 mm / 18 in

D 810 mm / 32 in

BACKWALL B 240 mm / 9.5 in E 405 mm / 16 in
CORNER

C 255 mm / 10 in F 595 mm / 23.5in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

A 405 mm / 16 in

D 760 mm / 30 in

BACKWALL B 240 mm / 9.5 in E 405 mm / 16 in
CORNER

C 215 mm / 8.5 in F 560 mm / 22 in

SIDEWALL

G 405 mm / 16 in

I 760 mm / 30 in

BACKWALL H 240 mm / 9.5 in J 405 mm / 16 in

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA:

LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA

VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR
METAL-FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE
REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND
SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OB-
STRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO
FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY
CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF
USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE
GLASS ONLY WITH NEOCERAM GLASS.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - ALCOVE

HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

102

CERTIFIED TO COMPLY WITH JULY 1990,

PARTICULATE EMISSION STANDARDS.

JAN

FEB

MAR

APR

MA

Y

JUN

JUL

AUG

SEPT

OCT

NOV

DEC

CAUTION

DA

TE OF MANUF

ACTURE

908-351a

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPER-
ATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK
OR 25 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE
WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVING ANOTHER APPLIANCE.

F3100L WITHOUT
AIRMATE SHIELD

F3100L

WITHOUT AIRMATE SHIELD

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

SIDEWALL

A 510 mm / 20 in D 860 mm / 34 in

BACKWALL B 355 mm / 14 in E 520 mm / 20.5 in
CORNER

C 265 mm / 10.5in F 610 mm / 24 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 510 mm / 20 in

D 860 mm / 34 in

BACKWALL B 305 mm / 12 in

E 470 mm / 18.5 in

CORNER

C 255 mm / 10 in

F 595 mm / 23.5 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

A 510 mm / 20 in

D 860 mm / 34 in

BACKWALL B 305 mm / 12 in

E 470 mm / 18.5 in

CORNER

C 215 mm / 8.5 in F 560 mm / 22 in

ALCOVE INSTALLATION

REQUIRES AIRMATE SHIELD

FLOOR

PROTECTION*

K

405 mm / 16 in

L

150 mm / 6 in

M

150 mm / 6 in

LISTED SPACE HEATER, SOLID FUEL TYPE, SUITABLE FOR
MOBILE HOME INSTALLATION

MODEL: REGENCY LARGE FREESTANDING STOVE -

F3100L

MANUFACTURED BY:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

6988 VENTURE ST.

DELTA, BC V4G 1H4

MADE

IN

CANADA

TESTED TO: ULC S627-00 / UL 1482-1998 / UL 737-2000

REPORT NO.6623 (MAY 93)

102

* In Canada, fl oor protection must
extend 18" to the front and 8" to
each side of the stove.

2008

2009

2010

COPY OF SAFETY LABEL FOR F3100L

Advertising