Installation – Regency Hampton H27 Medium Gas Stove User Manual

Page 23

Advertising
background image

Hampton

®

H27 Direct Vent Freestanding Gas Stove

23

INSTALLATION

Pipe Length (max. 18")

Part (6-5/8" Dia)

(4" Dia.)

Decorative

Wall Trim

Horizontal
Terminal
Part# 640-530/P

Wall Thimble

(required for

combustible walls)

Vinyl Siding
Standoff (Optional)
Part #946-205

Adapter

Part #946-219/P

(required)

RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES

MINIMUM HORIZONTAL TERMINATION INSTALLATIONS

You will require the following components with your new Hampton

®

Rear Vent Direct Vent Free-

standing Gas Stove. Please review your product to make sure you have everything you need. In
the event that you are missing any part, contact your dealer. Decorative brass or chrome trim kits
are available from Simpson Dura-Vent for their wall thimbles, as well
as a square wall thimble cover.

Planning Your venting Installation

See the "Exterior Vent Terminatal Locations"
section for requirements.
The H27 is approved
for a minimum horizontal termination with the
FPI Riser Vent Kit. See the diagram for minimum
and maximum pipe lengths.

When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (see the "Exterior Vent
Terminal locations" section) will be met.

*If this is an outside corner, the minimum distance
between the vent and the outside corner is 6"
(15cm). See "F" on the diagram in the "Exterior
Vent Terminal Locations" section.

NOTE: Ensure compliance with the outside
vent terminal location before cutting hole as
both dimensions must be met.

Note: These are the minimum pieces re-

quired. Other parts may be required
for your particular installation.

Minimum components for a Horizontal Installation:
640-944

Horizontal Termination Kit which includes:

1

6-5/8" Dia. x 18" Black Pipe

1

4" Dia. x 18" Aluminum Vent

1

Wall Penetration Heat Shield (Wall Thimble) (2 pcs)

1

640-530/P

Riser

Vent

Terminal

1

Decorative Wall Trim (Black)

1

948-128

Tube

Mill-Pac

Screws

946-219/P 1 Adapter

Optional Components:
946-204

45

o

Elbow - 6-5/8" Black pipe

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

Terminal

946-208/P Vent

Guard

FPI Riser Vent

#640-530/P

Max. 15-1/2"
(394mm)

Min. 2" (51mm)
If outside corner see note * above.

*

**Min.
6-1/2"

(165mm)

Max. 23-1/2"

(597mm)

Min. 3"
(76mm)

FPI
Riser
Vent
#640-530/P