Hampton

®

H27 Direct Vent Freestanding Gas Stove

SAFETY LABEL

This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove.
We have printed a copy of the contents here
for your review.

COPY OF SAFETY LABEL

NOTE: Hampton

®

units are constantly being

improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.

Listed:
Certified for/Certifi e pour:

VENTED GAS FIREPLACE HEATER

CANADA and U.S.A.

é

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

Й

Й

QUIP A L'UISINE POUR GAZ NATURAL

Й

Й

QUIP A L'UISINE POUR GAZ PROPANE

5"

WC/C.E. (1.25 kPa)

3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)

12"

WC/C.E. (3.00 kPa)

11" WC/C.E.

(2.74 kPa)

2.9" WC/C.E. (0.72 kPa)

Minimum supply pressure
Manifold pressure High
Manifold pressure Low

Minimum supply pressure
Manifold pressure High
Manifold pressure Low

DUPLICATE SERIAL NO.

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

351

351

Made in Canada/Fabrique au Canada

FPI Fireplace Products International Ltd. Delta, BC, Canada

Minimum Clearances to Combustibles/Degagement Minimum De Materiaux Combustibles

C 2" / 50mm
E 2"/50mm

A 6"/150mm
B 3"/75mm

Minimum ceiling height from top of unit:

mm

Minimum plafond hauteur en haut de
l'appareil: 24"/610mm

24"/610

Minimum clearance of Vent Terminal

to Outside Corner & Inside Corner:

with AstroCap 6"/150mm

with Dura-Vent Cap 12"/300mm

VENTED GAS FIREPLACE HEATER: This appliance must be installed in accordance with local codes, if any; if none,
follow:the national Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.Electrical
Supply (115 V, 1.13A, 60 Hz). This vented gas fireplace heater is not for use with filters.

: Installer l`appareil selon les codes ou reglements locaux, ou, en l`absence de tels

r glements, selon les codes

installation ANS Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.

Not for use with solid fuels.

FOYER AU GAZ À ÈVACUATION

è

d’

I

Alimentation

électrique. Ne doit pas être utilisé avec un combustible solide.

Serial No./ No de serie

918-813

Maximum Input
Minimum Input
Orifice size
Altitude

Maximum Input
Minimum Input
Orifice size
Altitude

FACTORY EQUIPPED FOR NATURAL GAS

Model:H27-NG

FACTORY EQUIPPED FOR PROPANE GAS

Model:H27-LP

Pression d'allimentation minimum
Pression

la tubulure d' chappement lev e

Pression

la tubulure d' chappement basse

а
а

й

й

й

й

Pression d'allimentation minimum
Pression

la tubulure d' chappement lev e

Pression

la tubulure d' chappement basse

а
а

й

й

й

й

E

E

A

A

B

Left Side Wall

Right Side Wall

Horizontal

Pipe

25,000 Btu/h (7.32 Kw/h)
12,500 Btu/h (3.66 Kw/h)
#42 DMS

(2.37mm)

0-4500 ft/pi (0-1372m)

23,000 Btu/h (6.74 Kw/h)
11,500 Btu/h (3.37 Kw/h)
#54 DMS

(1.4mm)

0-4500 ft/pi (0-1372m)

D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude

й
й

D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude

й
й

A

Left Side Wall

Right Side Wall

C

Vertical

Pipe

WN# 16378
Tested to:
Gas-Fired Appliances For Use At High

Altitudes CGA 2-17-M91,

ANSI Z21.88a-2007/CSA 2.33a-2007

Vented Gas Fireplace Heaters

See Manual for details

Model/Modele:

H27-NG

Model/Modele:

H27-LP

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the
Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720
and a CO alarm with battery back up in the same room where the gas appliance is installed.